Fire Services Act|第 9 條|消防|Act|In Force
第 二 章|內政部|v1.0
Effective Date: 2025-06-01|Last Amended: 2024-11-29
The administrator of a variety of places specified in the first paragraph of Article 6 shall conduct regular inspection and maintenance of fire safety equipment in accordance with the following provisions; the inspection results shall be reported to the competent authority where the site is located for review within the prescribed time limit, and the competent authority may send personnel for re-inspection; The same shall apply to the case of business closure or suspension of business. However, if the entire building where the various sites are located is no longer in use, the administrator of the site may be exempted from regular inspections of fire safety equipment and declaration of inspection results after reporting to the local competent authority for review and approval until the building is restored to use: 1.High-rise buildings, underground buildings, or places announced by the central competent authority: entrust a professional fire safety equipment inspection and maintenance institute permitted by the central competent authority to handle. 2.Places above a certain scale other than those in the preceding paragraph: entrust a fire protection equipment engineer or a fire protection equipment technician. 3.Places other than the preceding two paragraphs that are only equipped with non-systematic fire safety equipment such as fire extinguishers, sign equipment or emergency lighting: entrust a fire protection equipment engineer , a fire protection equipment technician or the administrator to manage it. Items, methods, standards, and frequency of regular inspection and maintenance of the safety equipment in various places (including out of business or closed places) in the preceding paragraph, periodic inspection or calibration of necessary equipment and appliances for maintenance, specifications, styles, additional methods and locations of maintenance completion signs, the reporting period for acceptance of inspection results, the inspection and handling methods when applying for review, the criteria for determining that the entire building is no longer in use, and the documents to be prepared for review and other matters to be complied with shall be prescribed by the central competent authority. Places above a certain scale in Subparagraph 2 of Paragraph 1 shall be announced by the central competent authority. The central competent authority shall prescribe qualifications, procedures, documents to be prepared, review methods, verification (renewal) issuance of licenses, valid period, modification, abolition, extension, regulations of business execution, the employment, changes, training of fire protection equipment engineer or technician, preparation and retention period of business- related documents, reporting of various forms and other matters to be obeyed by a professional fire safety equipment inspection and maintenance institute specified in Subparagraph 1 of Paragraph 1.